Accession Number : AD0428907

Title :   RESEARCH ON STORAGE TARGETS FOR CAMERA TUBES.

Descriptive Note : Final rept., July 62-Sep 63,

Corporate Author : WESTINGHOUSE ELECTRIC CORP PITTSBURGH PA

Personal Author(s) : Boerio,A. H.

Report Date : JAN 1963

Pagination or Media Count : 26

Abstract : An applied research program is described on Secondary Electron Conduction (SEC) targets. The techniques used in fabricating the SEC layer, including its supporting member, are described in detail. The problems encountered in manufacturing and handling are reported and the necessary precautions outlined. Some of the more frequently occurring defects, like target blemishes and crazing, were investigated. As a result, a satisfactory control over target quality was achieved including the processing of complete tubes. (Author)

Descriptors :   (*CATHODE RAY TUBE SCREENS, SECONDARY EMISSION), ELECTRICAL CONDUCTIVITY, MANUFACTURING, DISTORTION, CAMERA TUBES, PROCESSING, ALUMINUM COMPOUNDS, OXIDES, POTASSIUM COMPOUNDS, CHLORIDES

Distribution Statement : APPROVED FOR PUBLIC RELEASE