Accession Number : AD0482637

Title :   PM-1 NUCLEAR POWER PLANT CATEGORY III SYSTEM/COMPONENT TESTS,

Corporate Author : MARTIN CO MIDDLE RIVER MD NUCLEAR DIV

Personal Author(s) : Hassell ,Leigh D. ; Hall ,William C. ; Reichelsdorfer ,Peter ; Dugas ,Ronald ; Zachman,Howard C.

Report Date : MAY 1966

Pagination or Media Count : 182

Abstract : Performance testing data were compiled and evaluated for 13 specific performance evaluation areas. Each is detailed as a section of the report. It was concluded that further consideration should be given to improve the performance of: the main air cooled condenser, the main generator frequency and voltage control, over-all instrumentation calibration and general control system tuneup, the primary coolant makeup source and the tritium levels in the primary systems. Remedial action may be required in certain of these areas.

Descriptors :   (*NUCLEAR POWER PLANTS, PERFORMANCE(ENGINEERING)), (*NUCLEAR ENGINEERING, ENVIRONMENTAL TESTS), REACTOR COOLANTS, HEAT EXCHANGERS, HEAT TRANSFER, REACTOR SHIELDING MATERIALS, ELECTRIC POWER PRODUCTION, ELECTRICAL EQUIPMENT, STEAM CONDENSERS, RADIOACTIVE DECAY, RADIOACTIVE ISOTOPES, RADIOACTIVE WASTES, RADIOCHEMISTRY, GENERATORS, MEASURING INSTRUMENTS, CALIBRATION, REACTOR CONTROL, REACTOR SAFETY SYSTEMS, THERMAL ANALYSIS, MECHANICAL ENGINEERING, HYDRODYNAMICS, TRITIUM, REACTOR INSPECTION, CONTAMINATION, NEUTRON FLUX

Subject Categories : Radiation and Nuclear Chemistry
      Nuclear Power Plants and Fission Reactor Eng
      Nuclear Radiation Shield, Protection & Safety

Distribution Statement : APPROVED FOR PUBLIC RELEASE