Accession Number : AD0612469

Title :   DEVELOPMENT OF MILLIMETER AND SUBMILLIMETER MASER DEVICES.

Descriptive Note : Interim technical rept. no. 6, 1 11 Nov 64-28 Feb 65,

Corporate Author : WESTINGHOUSE DEFENSE AND SPACE CENTER BALTIMORE MD

Personal Author(s) : Hughes,W. E. ; Kremenek,C. R. ; Richards,W. E.

Report Date : 28 FEB 1965

Pagination or Media Count : 42

Abstract : The major effort was directed toward the operation of masers in the absence of an applied external magnetic field. The effort was divided into two specific areas; i.e., 9.3 gc and 81 gc. Zero field masers were successfully operated in both areas and the description of their operation comprises the bulk of this report. Each maser is described in detail and the conclusions drawn from experiments are given. (Author)

Descriptors :   (*MASERS, OPERATION), X BAND, MATERIALS, POWDERS, SINGLE CRYSTALS, ALUMINUM COMPOUNDS, NITRATES, TITANIUM COMPOUNDS, DIOXIDES, RUTILE, IMPURITIES, IRON, CRYSTAL GROWTH, MAGNETIC FIELDS, CAVITY RESONATORS, ELECTROMAGNETIC PUMPS, GAIN, TRAVELING WAVE TUBES, WAVEGUIDES

Distribution Statement : APPROVED FOR PUBLIC RELEASE