Accession Number : AD0633850

Title :   LOSSY CONDUCTORS FOR ATTENUATION OF POWER LINE INTERFERENCE.

Descriptive Note : Final technical rept. May 62-Oct 64,

Corporate Author : NAVAL CIVIL ENGINEERING LAB PORT HUENEME CALIF

Personal Author(s) : Clark,D. B.

Report Date : MAY 1966

Pagination or Media Count : 72

Abstract : The installation of overhead and underground lossy power conductors at the Hawaiian Tracking Station, South Point, Hawaii, has been tested, and the results show that the conducted and radiated interference from the power line are greatly reduced. Measurements of attenuated interference covered the frequency range from 14 kHz to 1,000 MHz. A comparison to previously installed lossy lines shows that the Hawaii line, composed of the latest developments in lossy conductors, is the most effective in attenuating interference. (Author)

Descriptors :   (*TRANSMISSION LINES, ATTENUATION), (*RADIOFREQUENCY INTERFERENCE, TRANSMISSION LINES), ELECTRIC CABLES, POWER, HAWAII, TRACKING

Subject Categories : Electrical and Electronic Equipment
      Electric Power Production and Distribution

Distribution Statement : APPROVED FOR PUBLIC RELEASE