Accession Number : AD0639108

Title :   PRODUCTION ENGINEERING MEASURE CRYSTAL UNIT CR(XM-46A)/U.

Descriptive Note : Quarterly progress rept. no. 13, 1 Feb-1 May 66.

Corporate Author : LEWIS (E B) CO INC EAST HARTFORD CONN

Report Date : 01 MAY 1966

Pagination or Media Count : 22

Abstract : The plateback technique and its control of spurious responses as used on the preproduction samples is discussed. The data obtained on testing the preproduction samples is presented and the methods of test are discussed. Tests for aging present a problem and its solution by substituting the bridge circuit for the TS-683 test circuit is presented. (Author)

Descriptors :   (*CRYSTAL FILTERS, MANUFACTURING), PERFORMANCE(ENGINEERING), VERY HIGH FREQUENCY, QUARTZ

Subject Categories : Electrical and Electronic Equipment
      Mfg & Industrial Eng & Control of Product Sys

Distribution Statement : APPROVED FOR PUBLIC RELEASE