Accession Number : AD0648068

Title :   LIVE-FIRE SCORING SYSTEM STUDY.

Descriptive Note : Final rept. on phases 2 and 3,

Corporate Author : STANFORD RESEARCH INST MENLO PARK CALIF

Personal Author(s) : Heintz,R. M. ; Steele,C. M. ; Albachten,H. T.

Report Date : SEP 1966

Pagination or Media Count : 114

Abstract : The report is divided into two sections, one dealing with miss-distance indicators and the other with hit detection. Discussions of existing and proposed techniques are given, and the specific applications to CDCEC problems considered. Acoustic techniques of shock-wave measurement were selected for experimental investigation as miss-distance indicators. The mathematical analysis and experimental results are given in Appendices A and B. Problems of shock-wave-arrival-time systems are analyzed in Appendix C. (Author)

Descriptors :   (*FIRING ERROR INDICATORS, DETECTORS), MEASUREMENT, ACOUSTIC DETECTORS, TARGETS, ELECTROMAGNETIC RADIATION, SHOCK WAVES, ACCURACY, PERFORMANCE(HUMAN), EXPERIMENTAL DATA, MATHEMATICAL ANALYSIS

Subject Categories : Fire Control and Bombing Systems

Distribution Statement : APPROVED FOR PUBLIC RELEASE