Accession Number : AD0673112

Title :   RAPID METHOD FOR DETERMINING QUALITY OF STANNATE IMMERSION COATINGS.

Descriptive Note : Final rept.,

Corporate Author : ARMY COATING AND CHEMICAL LAB ABERDEEN PROVING GROUND MD

Personal Author(s) : Deaver,William H. ; Brady,Howard S.

Report Date : JUL 1968

Pagination or Media Count : 22

Abstract : The report covers the development of a rapid means for determining the quality of a deposited stannate immersion coating. An apparatus was designed to measure the quantity of hydrogen gas evolved when a magnesium-steel couple is placed in an electrolyte. It was shown that this method could be used as a rapid means for evaluating the quality of stannate immersion coatings. (Author)

Descriptors :   (*CORROSION INHIBITION, COATINGS), (*STANNATES, DIP COATING), (*COATINGS, TEST METHODS), MAGNESIUM, STEEL, ELECTROLYTIC CELLS, ELECTROLYTES, HYDROGEN, SALT SPRAY TESTS

Subject Categories : Coatings, Colorants and Finishes
      Properties of Metals and Alloys
      Test Facilities, Equipment and Methods

Distribution Statement : APPROVED FOR PUBLIC RELEASE