Accession Number : AD0687864

Title :   SOME COMMENTS ON THE EFFECT OF GAGE LENGTH IN DYNAMIC STRAIN MEASUREMENT.

Descriptive Note : Final rept.,

Corporate Author : AEROSPACE RESEARCH LABS WRIGHT-PATTERSON AFB OHIO

Personal Author(s) : Pottinger,Marion G.

Report Date : JAN 1969

Pagination or Media Count : 52

Abstract : The effect of strain gage length on the transducing of common pulses and continuous sinusoids is summarized. A graphical method for approximating the response to a general pulse is presented. (Author)

Descriptors :   (*PIEZOELECTRIC TRANSDUCERS, STRAIN GAGES), (*STRAIN GAGES, ELECTROMAGNETIC PULSES), RELIABILITY, STRAIN(MECHANICS), LOADS(FORCES), INSTRUMENTATION, MATHEMATICAL ANALYSIS, MEASUREMENT

Subject Categories : Test Facilities, Equipment and Methods

Distribution Statement : APPROVED FOR PUBLIC RELEASE