Accession Number : AD0696508

Title :   CAPACITOR ANALYSIS. EVALUATION REPORT,

Corporate Author : GENERAL ELECTRIC CO SCHENECTADY N Y RESEARCH AND DEVELOPMENT CENTER

Personal Author(s) : Blok,Johan

Report Date : 31 JUL 1969

Pagination or Media Count : 41

Abstract : Capacitors become hot during operation due principally to dielectric losses in the capacitor dielectric. Heat pipes were used to extract this heat and thus permit the capacitor to operate at higher power levels. The capacitor/heat pipe geometry used in these experiments permits roughly a twofold increase in power level. It is anticipated that optimizing the heat transfer design will give as much as a 20-fold increase in power handling capacity. (Author)

Descriptors :   (*CAPACITORS, COOLING), (*DIELECTRICS, THERMAL STABILITY), ELECTROLYTIC CAPACITORS, PAPER CAPACITORS, HEAT EXCHANGERS, PIPES, COST EFFECTIVENESS, POWER

Subject Categories : Electrical and Electronic Equipment