Accession Number : AD0743912

Title :   Condition Survey, Sherman Airfield, Fort Leavenworth,

Corporate Author : ARMY ENGINEER WATERWAYS EXPERIMENT STATION VICKSBURG MISS

Personal Author(s) : Vedros,P. J. ; Jackson,R. D.

Report Date : JUN 1972

Pagination or Media Count : 15

Abstract : The purpose of the report is to present the results of an inspection performed at Sherman Army Airfield (SAAF) in April 1971. The inspection was limited to visual observations, and no tests were conducted on any of the pavement facilities. (Author)

Descriptors :   (*PAVEMENTS, VISUAL INSPECTION), (*RUNWAYS, KANSAS), MILITARY FACILITIES, STATISTICAL ANALYSIS, PERFORMANCE(ENGINEERING), CONSTRUCTION, CRACKS

Subject Categories : Terminal Flight Facilities
      Civil Engineering

Distribution Statement : APPROVED FOR PUBLIC RELEASE