Accession Number : AD0750582

Title :   A Comparison between Automated and Manual Assays of Adenosine Triphosphate and 2.3-Diphosphoglycerate in Blood.

Descriptive Note : Interim rept.,

Corporate Author : ARMY MEDICAL RESEARCH LAB FORT KNOX KY

Personal Author(s) : Kocholaty,Walter F. ; Dawson,R. Ben , Jr. ; Auwarter,Alan G. ; Billings,Thomas A. ; Crater,Davis

Report Date : 16 AUG 1972

Pagination or Media Count : 12

Abstract : Twenty samples of normal blood for levels of ATP and 2,3-DPG were assayed; values obtained by automated assay were consistently and considerably higher than those obtained by the manual method. (Author)

Descriptors :   (*ORGANIC PHOSPHORUS COMPOUNDS, *BLOOD CHEMISTRY), (*ADENOSINE PHOSPHATES, BLOOD CHEMISTRY), AUTOMATION, PHOSPHATES, VOLUMETRIC ANALYSIS, ENZYMES, HYDRAZONES

Subject Categories : Biochemistry

Distribution Statement : APPROVED FOR PUBLIC RELEASE