Accession Number : AD0772941

Title :   Temperature Measurement and Warning Systems.

Descriptive Note : Technical rept.,

Corporate Author : WATERVLIET ARSENAL N Y

Personal Author(s) : Frankel,Herbert

Report Date : DEC 1973

Pagination or Media Count : 24

Abstract : A thermistor varies the frequency of a tiny oscillator mounted on a gun tube. The temperature signal is received 6 inches away. This avoids the breakage of thermocouple wires because of recoil. A thermistor causes a circuit to oscillate when a gun tube reaches 350F. One wire, fastened to the gun mount instead of the tube, allows a small receiver to warn personnel when the critical temperature is reached. (Author)

Descriptors :   *GUN BARRELS, TEMPERATURE MEASURING INSTRUMENTS, *TEMPERATURE WARNING SYSTEMS, THERMISTORS, COOK OFF, THERMAL PROPERTIES, TEMPERATURE

Subject Categories : Test Facilities, Equipment and Methods
      Guns