Accession Number : AD0781224

Title :   Study of Operating Modes of Diesel Locomotive Alkaline Storage Batteries (Povyshenie Effektivnosti Elektricheskoi Peredachi Teplovozov),

Corporate Author : ARMY FOREIGN SCIENCE AND TECHNOLOGY CENTER CHARLOTTESVILLE VA

Personal Author(s) : Koshevoi,V. A.

Report Date : 08 AUG 1973

Pagination or Media Count : 14

Abstract : The paper discusses an analysis of processes occurring during operation of iron-nickel batteries. In the range of above-zero temperatures (C), the capacity of batteries in the starter discharge mode is limited by the positive electrode, not the negative electrode. The battery charging voltage of 75 v (1.63 v/element) currently used causes extreme overcharging of batteries and excessive heating. This significantly reduces the service life of batteries and decreases their operating reliability.

Descriptors :   *Alkaline batteries, *Diesel engines, Performance(Engineering), Storage batteries, Translations, USSR

Subject Categories : Electrochemical Energy Storage