Accession Number : AD0784866

Title :   Balloon-Borne Aerosol Counter Modifications, Particle Sizing Accuracy Tests.

Descriptive Note : Final rept. 1 Nov 73-15 Sep 74,

Corporate Author : EPSILON LABS INC BEDFORD MASS

Personal Author(s) : Miranda,Henry A. , Jr. ; Dulchinos,John ; Miranda,Henry P.

Report Date : JUL 1974

Pagination or Media Count : 32

Abstract : This report describes refurbishing work performed on the AFCRL aerosol counter which had sustained damage on the last of three successive stratospheric balloon flights in 1973. Certain improvements in the signal processing circuitry and associated software, which simplify the background level determination procedure and generate useful in-flight diagnostic information, are also described. In addition the results of exploratory tests to examine the combined effects of polarized illumination and particle shape as well as index of refraction on the sizing accuracy of the counter, are presented. Particles from several types of polishing compounds were nebulized and the size distribution as measured by the aerosol counter were compared with scanning electron microscope data. (Author)

Descriptors :   *Aerosols, *Counters, *Stratosphere, *Troposphere, Balloon equipment, Electron microscopes, Samplers, Signal processing, Logic devices, Particle size

Subject Categories : Atmospheric Physics

Distribution Statement : APPROVED FOR PUBLIC RELEASE