Accession Number : AD0786883

Title :   Cable Shield Test Facility.

Descriptive Note : Final rept. 10 May-30 Oct 73,

Corporate Author : STANFORD RESEARCH INST MENLO PARK CALIF

Personal Author(s) : Vance,E. F. ; Wadsworth,W. C.

Report Date : SEP 1974

Pagination or Media Count : 57

Abstract : A test facility for measuring the transfer impedance and transfer admittance of cable shields was designed, fabricated, and tested. The tester was designed for use with a network analyzer in the frequency range between 10 kHz and 100 MHz. With adapters provided with the tester, it can also be used to test shielded cable connectors over this frequency range. The facility was tested with tubular shields, with a slit pipe, and, for the connector test configuration, with a pipe with four holes about its girth. (Author

Descriptors :   *Test Facilities, *Electric cables, *Electromagnetic shielding, Electric connectors, Transfer, Electrical impedance, Admittance, Leakage(Electrical)

Subject Categories : Electrical and Electronic Equipment
      Test Facilities, Equipment and Methods

Distribution Statement : APPROVED FOR PUBLIC RELEASE