Accession Number : AD0800797

Title :   QUALIFICATION TEST OF SEPARATION JUNCTION BOX 1323403, MODEL 8205,

Corporate Author : LOCKHEED MISSILES AND SPACE CO INC SUNNYVALE CA

Personal Author(s) : Lundberg, V. C.

Report Date : 16 NOV 1961

Pagination or Media Count : 1

Abstract : The purpose of this test was to qualify one Separation Junction Box, 1323403, Model 8205 to Test Procedure RT-323403. The specimen was functionally tested. This consisted of monitoring all summing voltages and checking continuity. Following the initial functional tests, the specimen was subjected to vibration, shock, acceleration, temperature-humidity and altitude environments. The specimen performance met all requirements of the Qualification Test Procedure No. RT-323403. (Author)

Descriptors :   (*JUNCTION BOXES, PERFORMANCE(ENGINEERING)), TEST EQUIPMENT, MILITARY REQUIREMENTS, ACCEPTABILITY, INSTRUMENTATION, VOLTAGE, VIBRATION, ACCELERATION, TEMPERATURE, HUMIDITY, HIGH ALTITUDE, SHOCK(MECHANICS), CHECKOUT PROCEDURES, SPECIFICATIONS, ENVIRONMENTAL TESTS, VISUAL INSPECTION.

Subject Categories : Electrical and Electronic Equipment

Distribution Statement : APPROVED FOR PUBLIC RELEASE