Accession Number : AD0800921

Title :   QUALIFICATION OF LMSC 1315258 SECONDARY GUIDANCE JUNCTION BOX,

Corporate Author : LOCKHEED MISSILES AND SPACE CO INC SUNNYVALE CA

Personal Author(s) : Rosenbrock, E. J.

Report Date : 19 JAN 1962

Pagination or Media Count : 1

Abstract : The test specimen was subjected to a functional test prior to the environmental tests. Following the functional test, the specimen was exposed to environments of vibration, shock, acceleration, temperature and altitude. The test specimen performed satisfactorily in all environments to which it was subjected. The pre-environmental continuity check disclosed an incorrect value resistor; however, this resistance did not effect the performance of the test specimen in the electrical tests to which it was subjected.

Descriptors :   (*JUNCTION BOXES, RELIABILITY(ELECTRONICS)), VIBRATION, IMPACT SHOCK, TEMPERATURE, ALTITUDE, ELECTRICAL PROPERTIES, ENVIRONMENTAL TESTS.

Subject Categories : Electrical and Electronic Equipment