Accession Number : AD0825605

Title :   MULTIPLE PRESSURE TRANSDUCER BANKS AND THEIR APPLICATION,

Corporate Author : NAVAL ORDNANCE LAB WHITE OAK MD

Personal Author(s) : Risher, D. B.

Report Date : SEP 1967

Pagination or Media Count : 23

Abstract : The report describes the multiple pressure instrumentation being used in the Wind Tunnel Facilities at the Naval Ordnance Laboratory. Methods are described for obtaining rapid pressure stabilization and high speed data acquisition. The associated instrumentation which have been developed include a valve assembly for rapid transducer calibration, quick disconnect fittings for pressure tubes, and a remotely operated valve positioner. (Author)

Descriptors :   (*TRANSDUCERS, TEST FACILITIES), (*WIND TUNNELS, INSTRUMENTATION), VALVES, CALIBRATION, STABILIZATION, PRESSURE GAGES, DISCONNECT FITTINGS, POSITIONING DEVICES(MACHINERY), VACUUM APPARATUS, REMOTE CONTROL, DATA PROCESSING.

Subject Categories : Test Facilities, Equipment and Methods