Accession Number : AD0827632

Title :   ENGINEERING TEST OF POWER SUPPLY PP-4763()/GRC.

Descriptive Note : Final rept.,

Corporate Author : ARMY ELECTRONIC PROVING GROUND FORT HUACHUCA AZ

Personal Author(s) : Lynn, Robert E.

Report Date : DEC 1967

Pagination or Media Count : 72

Abstract : Engineering bench tests of the Power Supply PP-4763( )/GRC were conducted in the laboratory and engineering field tests were conducted using the test item with Radio Teletypewriter Sets AN/GRC-122 and AN/GRC-142. Six shortcomings were found during the engineering tests. Of these, only the requirement for a high voltage warning notice was significant enough to require correction. From an engineering standpoint, the test item is considered adequate, safe to operate, and compatible with Radio Set AN/GRC-106 and its teletypewriter configurations AN/GRC-122 and AN/GRC-142.

Descriptors :   *POWER SUPPLIES), (*RECTIFIERS, ELECTRICAL PROPERTIES, RADIOFREQUENCY INTERFERENCE, HUMIDITY, SALT SPRAY TESTS, SAND, DUST, FUNGI, IMPACT SHOCK, VIBRATION, RADIO EQUIPMENT, TELETYPE SYSTEMS, TRANSIENTS.

Subject Categories : Electrical and Electronic Equipment

Distribution Statement : APPROVED FOR PUBLIC RELEASE