Accession Number : AD0832298

Title :   L02 RELIEF AND SHUTOFF VALVE, PRESSURE SENSITIVE CONTROLLER, AND DIFFERENTIAL PRESSURE SWITCH CHECKOUT AND 'END TO END' CALIBRATION OF THE LOP MISSILE FUEL AND L02 PRESSURE METERS, COMPLEX 576-A,

Corporate Author : GENERAL DYNAMICS/ASTRONAUTICS SAN DIEGO CA

Personal Author(s) : Dekker, G.

Report Date : 23 JUN 1959

Pagination or Media Count : 13

Abstract : The document provides a procedure for the functional checkout of the Liquid Oxygen Relief and Shut-Off Valve, Pressure Sensitive Controller, and the Differential Pressure Switch after the Missile is erected in the tower and connected to Launch Control Circuitry. In addition, a procedure for the 'end to end' of the L02 and Fuel Tank Pressure Meters is provided. (Author)

Descriptors :   *PROPELLANT CONTROL), (*LIQUID ROCKET OXIDIZERS, (*CUT OFF VALVES, CHECKOUT PROCEDURES), PRESSURIZATION, SURFACE TO SURFACE MISSILES, SAFETY VALVES, PRESSURE REGULATORS, PRESSURE SWITCHES, PRESSURE GAGES, OXYGEN, INSTRUCTION MANUALS, GUIDED MISSILE PERSONNEL, CALIBRATION.

Subject Categories : Pumps, Filters, Pipes, Tubing, Fittings & Vlvs
      Surface-launched Guided Missiles
      Liquid Rocket Propellants

Distribution Statement : APPROVED FOR PUBLIC RELEASE