Abstract : This report describes temperature tests conducted and results obtained on a D/AIG Filter-Servoamplifier Canister Prototype. The tests were performed for engineering evaluation and the temperature range considerably exceeded the required operating temperature range of + 40 degrees F. to +80 degrees F. (Author)

Descriptors :   (*SERVOAMPLIFIERS, RELIABILITY), SYNCHROS, TEST METHODS, TEMPERATURE, HUMIDITY, ELECTRIC FILTERS, GAIN, DRIFT, VOLTAGE.