Accession Number : AD0857138

Title :   Operation and Service Manual for ECS Primary O2 and Water System Low Pressure Leak Rate Tester 52E180194.

Corporate Author : MCDONNELL DOUGLAS ASTRONAUTICS CO ST LOUIS MO

Report Date : 06 DEC 1968

Pagination or Media Count : 26

Abstract : The purpose of the report is to familiarize personnel with the operation and service instructions for the Environmental Control System (ECS) Primary O2 and Water System Low Pressure Leak Rate Tester. The two configurations are physically and functionally identical. The report presents a description of the tester, its control and indicator functions, and service instructions for preventive maintenance. (Author)

Descriptors :   *MANNED SPACECRAFT, *SPACE STATIONS, *LEAKAGE(FLUID), CONTROLLED ATMOSPHERES, CHECKOUT PROCEDURES, SPACE CAPSULES, INSTRUCTION MANUALS, OXYGEN, WATER, CONTROL SYSTEMS, PRESSURE, CONTROL PANELS, MAINTENANCE, CHECKOUT EQUIPMENT, SPACECRAFT COMPONENTS.

Subject Categories : Manned Spacecraft
      Life Support Systems

Distribution Statement : APPROVED FOR PUBLIC RELEASE