Accession Number : AD0861788

Title :   Liquid Oxygen Pressure Sensing Line Response Time Test,

Corporate Author : GENERAL DYNAMICS/ASTRONAUTICS SAN DIEGO CA

Personal Author(s) : Michaels, B. ; Christman, W. ; Wegener, H. W.

Report Date : 03 OCT 1962

Pagination or Media Count : 23

Abstract : The object of this test was to evaluate the transient response of liquid oxygen pressure sensing lines and instrumentation transducers utilizing a dynamic pressure calibrator. Also the transient response characteristics were evaluated with an actual test explosion in a simulated missile sustainer Y Duct LOX Line. (Author)

Descriptors :   (*LAUNCH VEHICLES, TELEMETER SYSTEMS), (*PIEZOELECTRIC TRANSDUCERS, REACTION KINETICS), LIQUID ROCKET OXIDIZERS, INSTRUMENTATION, TRANSIENTS, DUCTS, EXPLOSIVE CHARGES, TEST METHODS.

Subject Categories : Test Facilities, Equipment and Methods
      Ground Support Sys & Facil For Space Vehicles

Distribution Statement : APPROVED FOR PUBLIC RELEASE