Accession Number : AD0870028

Title :   Converter, Liquid Oxygen.

Descriptive Note : Final rept. on materiel test procedure.

Corporate Author : ARMY TEST AND EVALUATION COMMAND ABERDEEN PROVING GROUND MD

Report Date : 04 MAY 1970

Pagination or Media Count : 11

Abstract : The Army service test procedure describes test methods and techniques for evaluating the performance and characteristics of liquid oxygen converters (or generators), and for determining their suitability for service use by the U. S. Army. The evaluation is related to criteria expressed in applicable qualitative materiel requirements (QMR), small development requirements (SDR), technical characteristics (TC), or other appropriate design requirements and specifications.

Descriptors :   (*OXYGEN, LIQUEFIED GASES), (*ARMY EQUIPMENT, TEST METHODS), TRANSPORTATION, SAFETY, RELIABILITY, MAINTENANCE, HUMAN FACTORS ENGINEERING, TEST EQUIPMENT, OPERATORS(PERSONNEL), VISUAL INSPECTION, INVENTORY, RECORDS, STANDARDS.

Subject Categories : Mfg & Industrial Eng & Control of Product Sys
      Test Facilities, Equipment and Methods

Distribution Statement : APPROVED FOR PUBLIC RELEASE