Accession Number : ADA017517

Title :   Air Pollution Engineering Special Study, Ambient Air Quality Instrument Study.

Descriptive Note : Rept. for 23 May-28 Jul 75,

Corporate Author : ARMY ENVIRONMENTAL HYGIENE AGENCY ABERDEEN PROVING GROUND MD

Personal Author(s) : Coats,William T.

Report Date : 20 NOV 1975

Pagination or Media Count : 18

Abstract : This study provides an evaluation of the accuracy and precision of selected SO2 and NO2 instruments. Instruments studied were Thermo Electron Corporation Model 43 SO2 analyzer, Lear Siegler, Inc., Model SM1000 SO2 analyzer, and Thermo Electron Corporation Model 14D NO2 analyzer.

Descriptors :   *Air pollution, Analyzers, Instrumentation, Performance tests, Nitrogen oxides, Sulfur oxides, Accuracy, Precision, Samplers, Monitors, Comparison

Subject Categories : Physical Chemistry
      Test Facilities, Equipment and Methods
      Air Pollution and Control

Distribution Statement : APPROVED FOR PUBLIC RELEASE