Accession Number : ADA112170

Title :   Automotive Cold-Start Carbon Monoxide Emissions and Preheater Evaluation.

Descriptive Note : Special rept.,

Corporate Author : COLD REGIONS RESEARCH AND ENGINEERING LAB HANOVER NH

Personal Author(s) : Coutts,Harold J

PDF Url : ADA112170

Report Date : Dec 1981

Pagination or Media Count : 37

Abstract : Fairbanks and Anchorage, Alaska, experience high wintertime ambient levels of carbon monoxide (CO). Emissions from starting automobile engines in cold weather are thought to be a major source of CO. A quantitative procedure for determining startup CO emissions was developed. The startup emissions were measured as a function of soak time at several low ambient temperatures. The performance of engine preheaters in reducing the startup CO at the various soak times and temperatures was estimated. The data scatter was too great to draw any firm conclusions; however, the length of cold-soak time appeared to have a stronger effect on cold-start CO emissions than did soak temperatures (0 to -30 C). Compared to no preheat, continuous preheat during an overnight cold soak can reduce the cold-start CO emissions by 20 to 90%.

Descriptors :   *Automotive vehicles, *Engines, *Starting, *Cold weather, Test and evaluation, Scattering, Low temperature, Carbon monoxide, Emission, Heating, Heaters, Air pollution, Control systems

Subject Categories : Combustion and Ignition
      Reciprocating and Rotating Engines

Distribution Statement : APPROVED FOR PUBLIC RELEASE