Accession Number : ADA113120

Title :   Aquifer Testing Dry Lake Valley, Nevada.

Descriptive Note : Final rept.

Corporate Author : FUGRO NATIONAL INC LONG BEACH CA

PDF Url : ADA113120

Report Date : 30 Nov 1981

Pagination or Media Count : 37

Abstract : Results of aquifer testing of the valley-fill aquifer in Dry Lake Valley, Nevada gave a drawdown in the low well of 44.8 feet after 239 hours of pumping at a discharge of 500 gallons per minute. This recovery method gave a transmissivity of 5200 feet 2/day for the shallow aquifer and 6500 feet 2/day for the deeper aquifer. (Author)

Descriptors :   *Aquifers, Water supplies, Nevada, Valleys, Air Force facilities, Surface to surface missiles, Site selection, Ground water, Water wells, Yield

Subject Categories : Hydrology, Limnology and Potamology
      Civil Engineering