Accession Number : ADA113593

Title :   Reaeration Tests, Enid Lake Outlet Works.

Descriptive Note : Final rept. May 78-Apr 80,

Corporate Author : ARMY ENGINEER WATERWAYS EXPERIMENT STATION VICKSBURG MS

Personal Author(s) : Tate,Charles H , Jr

PDF Url : ADA113593

Report Date : Feb 1982

Pagination or Media Count : 36

Abstract : This study presents the results of gas transfer tests of the outlet structure at Enid Lake, Miss. Radioactive tracers, krypton-85 and tritium, were used to determine the gas transfer characteristics of the outlet structure. The sampling technique isolated the effects of the outlet conduit, the trajectory between the conduit and the tailwater, and the submerged portion of the stilling basin. Dissolved oxygen measurements were taken in the conduit in an attempt to supplement the radioactive tracer data. (Author)

Descriptors :   *Aeration, Mississippi, Reservoirs, Water, Release, Troposphere, Gases, Transfer, Measurement, Tracer studies

Subject Categories : Civil Engineering

Distribution Statement : APPROVED FOR PUBLIC RELEASE