Title :   Rotating Stall in an Axial Flow Single Stage Compressor. On-Blade Velocity Measurements.

Descriptive Note : Final rept. 15 Jan 80-14 Feb 82,

Corporate Author : VON KARMAN INST FOR FLUID DYNAMICS RHODE-SAINT-GENESE (BELGIUM)

Personal Author(s) : Gyles,B ; Ligrani,P ; Breugelmans,F A E

PDF Url : ADA114627

Report Date : 15 Apr 1982

Pagination or Media Count : 112

Abstract : Three multiple hot wire sensors are developed and applied to a low speed axial compressor rotor blade. The multiple wire sensor design is based on the technique of the combined hot and cold wire in a parallel arrangement for the detection of flow separation and reversal. The sensors are used in the unstalled and stalled part of the compressor characteristics with one and two stall cells present. The signals are analyzed using the fast Fourier transform, power spectra and correlation techniques. (Author)

Descriptors :   *Stalling, *Hot wire anemometers, *Axial flow compressor blades, Flow separation, Rotation, Velocity, Experimental data, Fast Fourier transforms, Power spectra, Correlation techniques, Belgium

Subject Categories : Test Facilities, Equipment and Methods
      Fluid Mechanics
      Jet and Gas Turbine Engines

Distribution Statement : APPROVED FOR PUBLIC RELEASE