Accession Number : ADA114724

Title :   System Engineering Analysis of 600 PSI Boilers Installed on AFS-1, AOE-1, AOR-1, and AO-177 Class Ships,

Corporate Author : ARINC RESEARCH CORP ANNAPOLIS MD

Personal Author(s) : Wilson,C E ; Beyers,C P

PDF Url : ADA114724

Report Date : Apr 1982

Pagination or Media Count : 121

Abstract : This report documents the historical maintenance experience for the 600 psi propulsion boiler system (ship's work authorization boundary (SWAB) 221-1), the boiler blow system (SWAB 221-2), and the boiler steam escape system (SWAB 221-4) installed on AFS-1, AOE-1, AOR-k, and AO-1 Class ships. It presents an analysis of the existing maintenance policy and recommends maintenance actions and policy modifications to improve system material condition.

Descriptors :   *Boilers, *Maintenance management, Steam turbines, Systems engineering, Tanker ships, Systems analysis, Refractory materials, Valves, Boiler tubes, Auxiliary, Maintenance, Scheduling, Naval logistics