Accession Number : ADA275966

Title :   One Million BTU/Hour Pilot Plant Study for Morrison-Knudsen Engineers on RMA Basin F Liquid,

Corporate Author : THERMAL RESEARCH AND ENGINEERING CORP CONSHOHOCKEN PA

Personal Author(s) : Campbell, Charles

Report Date : 01 APR 1989

Pagination or Media Count : 162

Abstract : A test burn was conducted on T-Thermal's LV-1 SUB-X incinerator pilot facility on February 21 through 23, 1989. The purpose of this test was to demonstrate the destruction efficiency obtained when using a T-Thermal incinerator system for the destruction of RMA basin F liquid waste. It was concluded that: (1) Aqueous waste will burn with natural gas used as auxiliary fuel and excess air rates between 19.3% and 51/4%; (2) Steam atomization is needed to keep the tip clean and co emissions at acceptable levels; and (3) The full scale unit should be operated at 1900 degrees F. This report includes descriptions of the equipment used and the test conditions. Data tables summarize the results from the various tests.

Descriptors :   *INCINERATORS, *WASTE DISPOSAL, *LIQUID WASTES, *AIR POLLUTION, *HEAT LOSS, *BURNING RATE, EMISSION CONTROL, HIGH TEMPERATURE, CARBON MONOXIDE, SAMPLING, HOT GASES, PENNSYLVANIA, HEAT TRANSFER, PILOT PLANTS, PILOT STUDIES, DATA ACQUISITION, HYDROCARBONS, VENTURI TUBES, SCRUBBERS, POLLUTION ABATEMENT, NATURAL GAS, DESIGN CRITERIA.

Subject Categories : Solid Wastes Pollution and Control
      Air Pollution and Control
      Thermodynamics