Accession Number : ADA293846

Title :   Engineering Evaluation of the MEMCOR Small ROWPU.

Descriptive Note : Final rept.,

Corporate Author : TACOM RESEARCH DEVELOPMENT AND ENGINEERING CENTER WARREN MI

Personal Author(s) : Luu, Chuong A. ; Shalewitz, Bob

PDF Url : ADA293846

Report Date : FEB 1995

Pagination or Media Count : 43

Abstract : The Department of the Air Force, Strategic Air Command (SAC) at Offutt AFB, Nebraska, requested that the MTC-B assist in conducting the inspection and acceptance testing of a Small ROWPU designed and manufactured by MEMCOR. The evaluation included a seawater and freshwater test to determine whether the small ROWPU met the AF requirements outlined in this report. The results indicated that while the small ROWPU met water production and quality requirements, there were human factors and safety deficiencies that must be addressed.

Descriptors :   *REVERSE OSMOSIS, *WATER TREATMENT, *WATER POLLUTION CONTROL EQUIPMENT, TEST AND EVALUATION, ACCEPTANCE TESTS, REQUIREMENTS, AIR FORCE, PRODUCTION, HUMAN FACTORS ENGINEERING, FRESH WATER, ENGINEERING, DEFICIENCIES, SAFETY, QUALITY ASSURANCE, SEA WATER, STRATEGIC AIR COMMAND, NEBRASKA.

Subject Categories : Nuclear Weapons
      Water Pollution and Control

Distribution Statement : APPROVED FOR PUBLIC RELEASE