Accession Number : ADA308032

Title :   47-FT Motor Lifeboat Tactical Maneuvering Reverification Testing.

Descriptive Note : Final rept.,

Corporate Author : COAST GUARD RESEARCH AND DEVELOPMENT CENTER GROTON CT

Personal Author(s) : Macesker, Bert ; Desruisseau, Robert

PDF Url : ADA308032

Report Date : JAN 1996

Pagination or Media Count : 74

Abstract : Reverification testing was performed on a preproduction 47-FT Motor Lifeboat to obtain an updated view of maneuvering and control performance. Standard vessel test procedures were employed. The testing was done on the CG-47201 which was considered nearest in configuration to the production run 47-Fr Motor Lifeboats scheduled for delivery in 1997. The test results were compared to the performance on the prototype CG-472OO in 1991 and to data collected on the CG-47201 after changeout to DDEC engines in 1994.

Descriptors :   *PERFORMANCE TESTS, *LIFEBOATS, TEST AND EVALUATION, CONTROL, PRODUCTION, TEST METHODS, CONFIGURATIONS, STANDARDS.

Subject Categories : Marine Engineering