Accession Number : ADA954347

Title :   Arc Welding of Armor. Rolled, Homogeneous, 1 Inch Thick Armor Plate, Welded with Ferritic Electrode by the Allegheny Ludlum Steel Corporation and Heat Treated Subsequent to Welding.

Corporate Author : WATERTOWN ARSENAL MA

Personal Author(s) : Herres,S. A. ; Warner,W. L.

Report Date : 15 FEB 1943

Pagination or Media Count : 17

Abstract : The object is to carry out ballistic penetration test and metallurgical examination of subject plates. Ballistic limit of the welds, tested with .50 caliber A.P. M2 projectiles, is satisfactory. Metallurgical characteristics of the weld are satisfactory except for slag inclusions and undercutting which were revealed by radiographic inspection. No advantage is apparent from preheating since cracks were not formed in base metal of plate welded without preheat and since objectionable features of as-welded structure were eliminated by heat treatment subsequent to welding.

Descriptors :   ARC WELDING, ARMOR, ARMOR PLATE, BALLISTICS, BASE METAL, CRACKS, ELECTRODES, FERRITES, HEAT TREATMENT, INSPECTION, LIMITATIONS, METAL PLATES, METALLURGY, PENETRATION, PLATES, RADIOGRAPHY, STEEL, THICKNESS, WELDS

Subject Categories : Fabrication Metallurgy
      Ballistics

Distribution Statement : APPROVED FOR PUBLIC RELEASE