Accession Number : ADP000753

Title :   RBC (Rotating Biological Contactor) for BOD and Ammonia Nitrogen Removals at Princeton Wastewater Treatment Plant,

Corporate Author : ILLINOIS STATE WATER SURVEY PEORIA WATER QUALITY SECTION

Personal Author(s) : Lin,Shundar ; Evans,Ralph L. ; Dawson,Warren

Report Date : 1982

Pagination or Media Count : 27

Abstract : The RBC system at Princeton is designed as a secondary treatment for the removal of BOD5 and ammonia nitrogen. An intensive study on each stage under normal and artificial shock operations was carried out for over one year. This paper deals with preliminary evaluation of mean values.

Descriptors :   *Waste water, *Waste treatment, *Water treatment, *Municipalities, Facilities, Case studies, Ammonia, Nitrogen, Removal, Oxygen consumption, Operation

Distribution Statement : APPROVED FOR PUBLIC RELEASE